I-Airwoods I-Fresh Air Dehumidifier Energy Recovery Ventilation 350-900CMH/206-530CFM
{"prod-data3":{"prod-title":"<p>Airflow Range</p>","350 CMH":"https://ecdn6.globalso.com/upload/p/2082/image_other/2025-05/350-cmh.jpg","650 CMH":"https://ecdn6.globalso.com/upload/p/2082/image_other/2025-05/650-cmh.jpg","900 CMH":"https://ecdn6.globalso.com/upload/p/2082/image_other/2025-05/900-cmh.jpg"},"prod-data4":{"prod-title":"<p>Filter</p>","F8":"https://ecdn6.globalso.com/upload/p/2082/image_other/2025-05/f8-filter.jpg","Primary filter":"https://ecdn6.globalso.com/upload/p/2082/image_other/2025-05/p-filter.jpg","DP H13 HEPA filter (Disinfection)":"https://ecdn6.globalso.com/upload/p/2082/image_other/2025-10/h13-dp-filter.jpg"}}
1. Ukuhlanzwa
Umoya ohlanzekile wangaphandle udlula kusihlungi esiyinhloko nesihlungi se-F8 ohlangothini lwe-OA, ukuze kuboshwe uthuli' PM2.5/ okunye ukungcola.
2. Ukungenisa umoya kanye Nokubuyisela Ukushisa
Ngenisa umoya ohlanzekile wangaphandle ekamelweni futhi ukhiphe umoya omdala; Ibuyisela ukushisisa ebusika futhi ilulame ukupholisa ehlobo.
3. Ukupholisa/Ukushisa
Ngemuva kwesigaba sokuqala sokubuyiselwa kokushisa, umoya udlula ku-condensor ukuze uthuthuke/uphole.
4. Ukukhipha umswakama
Ama-airstreams amabili ahamba phakathi kwesishintshi sokushisa kanye ne-condensor, kungehlisa umswakama womoya omusha.
Ukunikezwa komoya ohlanzekile njalo ezindaweni ezingaphakathi endlini lapho sichitha khona isikhathi esingaphezu kuka-70% kubalulekile empilweni yethu. I-Airwoods heat pump energy recovery ventilator (HPERV) iwumkhiqizo omusha ohlanganisa ukuhlanzwa komoya omusha, ukufudumeza/ukupholisa, ukubuyiswa kokushisa, kanye nokuqeda umswakama emshinini owodwa. Ingakunikeza umoya okhululekile futhi onempilo wasendlini kuyilapho wonga amandla nemali. Ihlinzeka ngesixazululo esifanele sezakhiwo eziqinile emoyeni lapho amafasitela evame ukuhlala evaliwe ngenxa yomsindo, izinhlayiya zothuli nokulahlekelwa amandla.
Ngesishintshi sokushisa nesistimu yephampu yokushisa ngaphakathi, i-Airwoods HPERV iletha umoya ohlanzekile nohlanzekile ngesistimu yokubuyisela amandla kabili. Isibonelo, umoya ohlanzekile ongu-35'C ngesikhathi sasehlobo ungapholiswa ube ngu-23.5'C, kanti u-2'C umoya ohlanzekile ngesikhathi sasebusika ungafudumeza ufike ku-35.5'c. Ingasebenza njenge-air conditioner e-Autumn/Spring noma ebusuku, lapho ngaphandle ingu-10-28'C. Ngaphandle kwalokho, ingasusa umswakama owedlulele, ivimbele ukwakheka kwesikhunta sefenisha futhi igcine umoya wasendlini usezingeni lokushisa elithokomele kanye nomswakama.
Imikhiqizo Design
Isimiso Sokusebenza

Izinzuzo Uma ziqhathaniswa ne-ERV Ejwayelekile
| IZIMO ZASEHLOBO | |||
| Cha | Incazelo | Izinga lokushisa | Umswakama Ohlobene |
| 1 | Ngaphandle Kwezinga Lokushisa OA | 35℃ | 59.10% |
| 2 | Ngaphakathi Izinga lokushisa RA | 27℃ | 49.80% |
| 3 | Umoya Omusha (Amayunithi Okubuyisela Ukushisa Okujwayelekile) SA | 29.24°C | 55.48% |
| 4 | Umoya Omusha (Amayunithi Okubuyisela Ukushisa Kwephampu Yokushisa) SA | 23.5°C | 72.11% |
| IZIMO ZASEBUSIKA | |||
| Cha | Incazelo | Izinga lokushisa | Umswakama Ohlobene |
| 1 | Ngaphandle Kwezinga Lokushisa OA | 2℃ | 83.84% |
| 2 | Ngaphakathi Izinga lokushisa RA | 21°C | 39.16% |
| 3 | Umoya Omusha (Amayunithi Okubuyisela Ukushisa Okujwayelekile) SA | 15.68C | 73.57% |
| 4 | Umoya Omusha (Amayunithi Okubuyisela Ukushisa Kwephampu Yokushisa) SA | 35.56°C | 17.87% |
Ukwakheka Komkhiqizo
01 Abalandeli be-EC
Ukuze wonge amandla futhi uhlangabezane nezinga le-ERP2018, yakhiwe ngamamotho aya phambili e-EC anokulawula okungu-0-10 Voltage. Inezivinini ezingu-10 futhi ibonakala ngokudlidliza okuncane, umsindo ophansi, ukonga amandla, nempilo ende yesevisi.
02 Ukudlula
Ehlobo, i-bypass engu-100% inikela ekukhululekeni okuthuthukisiwe futhi ilawulwa ngokuzenzekelayo ngesisekelo samazinga okushisa angaphandle alinganisiwe.
03 Izihlungi Eziningi
Izihlungi ezijwayelekile izihlungi zebanga le-G4 ne-F8. Isihlungi esiyinhloko singasusa uthuli, impova nokunye ukungcola emoyeni omusha ongenayo. Ziphinde zivikele isishintshi sokushisa ekuvalelekeni noma ekugqwaleni. Futhi isihlungi se-F8 singaqhubeka nokuhlanza umoya. Ukusebenza kahle kokuhlunga kwezinhlayiyana ze-PM2.5 kungaphezu kwama-95%. Isihlungi esingazikhethela sokubulala amagciwane siyatholakala ngokusebenza kahle kokuhlunga.
04 DC Inverter Compressor
Iphuma kumkhiqizo owaziwa kakhulu i-GMCC. Icindezela futhi yandise isiqandisi ukuze sidlulise ukushisa phakathi kwemifudlana yomoya yangaphandle neyasendlini. Iwuhlobo lwe-inverter ye-DC olungalungisa isivinini nokuphuma kwayo ngokuvumelana nesidingo somthwalo, iqinisekise ukusebenza kokulondoloza amandla kanye nezinga eliphansi lomsindo. Ingasebenza futhi ebangeni lokushisa elibanzi elingu -15˚C kuya ku-50˚C. Zombili ifriji engu-R32 kanye ne-R410a iyatholakala.

I-Heat Exchanger

1. I-Cross-Counterflow Enthalpy Heat Exchanger
I-Cross-Counterflow Enthalpy Heat Exchanger Ingakwazi Ukudlulisa Ukushisa Nomswakama Phakathi Kwemifudlana Yomoya Yangaphandle Nasendlini Ngaphandle Kokukuxuba.
Ingalulama Kufike Ku-80% Wamandla Avela Emoyeni Okhipha Kahle, Yehlisa Ukushisisa Noma Ukupholisa Umthwalo Ku-Compressor. Iyagezeka Futhi Kulula Ukuyigcina. Inesikhathi sokuphila esifinyelela eminyakeni eyi-15.
2. Izinzuzo Zokushintshanisa
01. Induduzo Ethuthukisiwe Ngekhwalithi Yomoya Yasendlini Enhle Kakhulu
• Ukusebenza Kahle Ngokufika Ku-90% Ukubuyisela Ukushisa Nokufika Ku-80% Ukutholwa Komswakama.
• Awusekho Umoya Owomile Ebusika.
• Ukwehliswa Okujabulisayo Komswakama Ehlobo.
02. Ukuqina Okukhulisiwe Kwendwangu Yokwakha
Izinga Lokuswakama Okuqhubekayo Livimbela Imifantu Ezinto Ezibucayi Ezifana Nokwendlalelwa Ngokhuni Futhi Inwebe Isikhathi Sokuphila Kwaso.
03. Akukho Frosting Ngaphansi - 30˚C
Ngenxa Yokungeneka Okuphezulu Kwawo Kumangqamuzana Amanzi, Awekho Amanzi Okujiya Azokwakheka Phezulu Kwe-Membrane, Futhi Ukufingqa Nokuvinjelwa Kweqhwa Ngeke Kwenzeke Ngaphansi Kwezimo Ezidlulele Ze-30˚C.
04. Ukusebenza Kwezindleko Okuningi
Ukusebenza Kwamahhala Kwe-Condensate Ngaphansi Kwezimo Ezijwayelekile Kusho ukuthi Asikho Isidingo Somsele We-Condensate. Lokhu Konga Imali Yamakhasimende Akho.
Ukulawula & Imisebenzi
Iphaneli yokulawula kude ye-LCD ethuthukisiwe
01. Imodi Yokupholisa
02. Imodi Yokungenisa umoya
03. I-alamu yokuhlunga
04. Imodi yokushisa
05. Kumasethingi
06. Imodi yokunciphisa umswakama
07. Uhlobo Lwezinga lokushisa
08. Ijubane labalandeli
09. Isibali sikhathi Samasonto onke Sivuliwe/Cishiwe
10. Isibonisi Sezinga lokushisa
11. Usuku Lwesonto
12. Iwashi
13. Vula/Vala Inkinobho
14. Inkinobho yemodi
15. Inkinobho Ephezulu/Ephansi
16. Setha Inkinobho

2. Imisebenzi ye-Wifi
Umsebenzi We-Wifi Uyatholakala Ukuze Ulawule Futhi Ugade Uhlelo Lokungenisa umoya Kunoma yikuphi Emhlabeni Usebenzisa Ucingo Oluhlakaniphile. Umsebenzisi Angakwazi Ukuqapha Ikhwalithi Yomoya Wangaphakathi Esandleni Sakho Ukuze Uphile Ngendlela Enempilo.
A. Ukuqapha Ikhwalithi Yomoya Wasendlini
Gada Isimo Sezulu Sendawo, Izinga Lokushisa, Umswakamo, Ukugxila Kwe-Co2 Esandleni Sakho Ukuze Uphile Ngendlela Enempilo.
B. Isilungiselelo Esiguquguqukayo
Ukushintsha Okufika Ngesikhathi, Izilungiselelo Zesivinini, I-Bypass/ Isikhathi/I-alamu Yesihlungi/Isilungiselelo Sezinga lokushisa.
C. Ukulawulwa Kweqembu
• Ukulawula Okuhlakaniphile Ngokuhambisana Nesimo Sezulu Sendawo.
• Uhlelo lokusebenza olulodwa lungalawula amayunithi amaningi.
• Ukulawula Ukuxhumana Nezinye Izisetshenziswa Nge-Tuya Iot.
Idatha Yezobuchwepheshe
Imingcele Yezobuchwepheshe
| Imodeli | Iyunithi | I-AV-HTPF35/E132 | |
| Ukugeleza komoya okulinganiselwe | CMH | 350 | |
| I-Exhaust airflow (imodi yokungenisa umoya) | CMH | 350 | |
| I-Exhaust airflow (imodi yokushisisa/yokupholisa) | CMH | 350 | |
| Ingcindezi emile yangaphandle | Hhayi-ke | 100 | |
| Umsindo | I-dB(A) | 37/42 | |
| Amandla | 220V 1P 50/60Hz | ||
| Ubukhulu (LxWxH) | mm | 760x600x1000 | |
| I-air inlet/diameter ye-outlet | mm | 188 | |
| Ubude bokungena komoya/okukhiphayo | mm | 60 | |
| Ukuphakama kwesisekelo somshini | mm | 61.5 | |
| Ipayipi lokudonsa amanzi | Intshi | 1/2" | |
| Isiqandisi | R32 | ||
| Izinga lokushisa lokusebenza | ℃ | - 15-50 | |
| Imodi yokungenisa umoya | Izinga lokushisa Effi. (ukushisisa) | % | 76.5 |
| Izinga lokushisa Effi. (ukupholisa) | % | 72 | |
| Enthalpy Effi. (ukushisisa) | % | 72.6 | |
| Enthalpy Effi. (ukupholisa) | % | 69.4 | |
| Amandla okokufaka | M | 185 | |
| Okokufaka kwamanje | A | 1.08 | |
| Ukupholisa/Ukushisa | Umthamo wokupholisa ojwayelekile | IN | 3798 |
| Umthamo omkhulu wokupholisa | ≤ | 4173 | |
| Amandla okokufaka (ukupholisa) | M | 847 | |
| Ukusebenza kwamanje (ukupholisa) | A | 4.42 | |
| Umthamo wokushisa ojwayelekile | IN | 4604 | |
| Umthamo omkhulu wokushisisa | IN | 4981 | |
| Amandla okokufaka (ukushisisa) | IN | 790 | |
| Ukusebenza kwamanje (ukushisisa) | A | 3.82 | |
| *Amapharamitha ahlolwe i-accordion kumazinga we-EN308. | |||
Ubukhulu

Amadokhumenti

I-Airwoods DC INVERTER Impompi Yokushisa ERV 2.0 Ikhathalogi

I-Airwoods General Product Catalog

Isincomo




Izici Eziyinhloko